Enquire about Signal Converters

Signal Converters with HTL, TTL Frequency Input

Signal Converter Frequency Parallel FP210:

Signal Converter Parallel Frequency FP210

Signal Converter Parallel Frequency FP210

Short description on FP210:

The FP210 parallel frequency signal converter receives incremental signals via its frequency input and transfers them precisely and quickly into a parallel binary, gray code or BCD format. It is able to processes an input frequency up to 1 MHz and it is also possible to change the input to start-stop signals or SSI signals.

  • Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
  • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
  • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
  • Start-stop interface for absolute transducers and magnetostrictive sensors
  • Input frequency up to 1 MHz
  • 25-bit parallel output push-pull in BCD, binary or Gray code format
  • Power supply 18 ... 30 VDC
  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)

Download Brochure
Download Product Specifications

Get a Quote


Signal Converter Frequency Analog / Serial RS232/RS485 FU210:

Signal Converter Frequency Analog / Serial RS232/RS485 FU210

Signal Converter Frequency Analog / Serial RS232/RS485 FU210

Short description on FU210:

The Signal Converter Frequency Analog / Serial RS232/RS485 FU210 processes input signals as frequency or velocity information. It is able to read signals in the formats TTL / RS422, HTL differential, HTL PNP and HTL NPN up to 1 MHz and to convert them into a freely scalable analog measured variable (current / voltage) almost instantaneously. With a resolution of 16 bits, or as digital information via Modbus RTU, these converted signals are then available for further processing.

  • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
  • Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
  • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
  • Power supply 18 ... 30 VDC
  • Snap-on housing for top hat rail (according to EN 60715)
  • Setup via operator software OS6.0
  • Serial RS232- / RS485 interface
  • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
  • Start-stop interface for absolute transducers and magnetostrictive sensors
  • USB interface and RS232/RS485-interface for configuration and serial readout